7001 PenPrime
The 7001 PenPrime by ASTC Polymers is a single-component aromatic polyurethane primer designed to deliver exceptional adhesion, toughness, and corrosion resistance. It is a moisture-cure primer ideal for sealing and preparing surfaces exposed to demanding chemical and physical environments.
Applications
The 7001 PenPrime is suitable for:
- Polyurea Applications: Primer for all polyurea coatings.
- Concrete Floors: Primer prior to epoxy or urethane floor coatings.
- Metal Surfaces:
- Tanks, vessels, and structural steel.
- EPDM roofing for polyurea applications.
- Cold Environments: Ideal for expansion joints, airfields, and industrial settings.
Advantages
- Compatible with ASTC’s Crystal Matrix Waterproofing (CMW).
- Works on a variety of substrates, providing a strong cross-link with polyurea coatings.
- Accelerated set time available with an optional accelerator.
- Semi-flexible with excellent impact resistance.
- Effective in protecting concrete and steel from corrosion.
Coverage
- Dry film thickness: 2–3 mils per coat; heavier applications up to 8 mils for specific needs.
Preparation
- Concrete Surfaces:
- Ensure a 28-day cure before application.
- Remove curing agents, oils, wax, and other contaminants.
- Perform a moisture vapor test before application.
- Clean surfaces using an abrasive “brush-off” blast to provide a rough profile (minimum 2 mils).
- Seal/repair cracks, spalls, and voids with ASTC-approved products (e.g., 830, 4034, 3004).
- Metal Surfaces:
- Round off sharp edges and remove burrs, weld splatter, and rough welds.
- Clean thoroughly to eliminate contaminants.
- Achieve a 2-mil profile through sanding, grinding, or sandblasting.
- Use SSPC-SP standards for surface preparation:
- Severe Exposure: SSPC-SP-5 Near-White sandblasting.
- Mild Exposure: SSPC-SP10/NACE Near-White blast cleaning.
Curing Time and Temperature
- Set Time: 45 minutes to 1.5 hours.
- Cure Time: 2 hours at 70°F (environmental temperature affects curing).
- Application Temperature Range: 35°F to 125°F.
- Post-Application:
- Allow the product solvent to “flash” before applying the topcoat.
- If fully cured, sand/abrade the surface to create a profile before recoating.
Limitations
- Not for Wet Surfaces: Ensure all surfaces are clean and dry.
- Storage: Store at room temperature on wood pallets, away from direct sunlight.
- Environmental Conditions: Set time may vary with temperature and humidity.
Color
- Clear, honey-colored.
Health and Safety
- For professional applicators only.
- Wear protective clothing, goggles, and a NIOSH-approved mask.
- Use positive air supply in confined spaces.